Thermo-refractive and thermo-chemical noise in the beamsplitter of GEO600 gravitational-wave interferometer

Abstract

Braginsky, Gorodetsky, and Vyatchanin have shown that thermo-refractive fluctuations are an important source of noise in interferometric gravitational-wave detectors. In particular, the thermo-refractive noise in the GEO600 beamsplitter is expected to make a substantial contribution to the interferometer's total noise budget. Here we present a new computation of the GEO600 thermo-refractive noise which takes into account the beam's elliptical profile and, more importantly, the fact that the laser beam induces a standing electromagnetic wave in the beamsplitter. The use of updated parameters results in the overall reduction of the calculated noise amplitude by a factor of about 5 in the low-frequency part of the GEO600 band, compared to the previous estimates. We also find, by contrast with previous calculations, that thermo-refractive fluctuations result in white noise between 600 Hz and 39 MHz, at a level of 8.5· 10-24Hz-1/2. Finally, we describe a new type of thermal noise, which we call the thermo-chemical noise. This is caused by a random motion of optically-active chemical impurities or structural defects in the direction along a steep intensity gradient of the standing wave. We discuss the potential relevance of the thermo-chemical noise for GEO600.

0

Turn this paper into a lesson

ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.

Discussion (0)

Sign in to join the discussion.

Loading comments…