A complexity measure based method for studying the dependence of 222Rn concentration time series on indoor air temperature and humidity

Abstract

We have suggested a complexity measure based method for studying the dependence of measured 222Rn concentration time series on indoor air temperature and humidity. This method is based on the Kolmogorov complexity (KL). We have introduced (i) the sequence of the KL, (ii) the Kolmogorov complexity highest value in the sequence (KLM) and (iii) the KL of the product of time series. The noticed loss of the KLM complexity of 222Rn concentration time series can be attributed to the indoor air humidity that keeps the radon daughters in air.

0

Turn this paper into a lesson

ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.

Discussion (0)

Sign in to join the discussion.

Loading comments…