Improving Accuracy and Efficiency of Start-up Cost Formulations in MIP Unit Commitment by Modeling Power Plant Temperatures

Abstract

This paper presents an improved mixed-integer model for the Thermal Unit Commitment Problem. By introducing new variables for the temperature of each thermal unit, the off-time-dependent start-up costs are modeled accurately and with a lower integrality gap than state-of-the-art formulations. This new approach significantly improves computational efficiency compared to existing formulations, even if they only model a rough approximation of the start-up costs. Our findings were validated on real-world test cases using CPLEX.