Diffraction tomography with Fourier ptychography

Abstract

This article presents a method to perform diffraction tomography in a standard microscope that includes an LED array for illumination. After acquiring a sequence of intensity-only images of a thick sample, a ptychography-based reconstruction algorithm solves for its unknown complex index of refraction across three dimensions. The experimental microscope demonstrates a spatial resolution of 0.39 μm and an axial resolution of 3.7 μm at the Nyquist-Shannon sampling limit (0.54 μm and 5.0 μm at the Sparrow limit, respectively), across a total imaging volume of 2.2 mm × 2.2 mm × 110 μm. Unlike competing methods, the 3D tomograms presented in this article are continuous, quantitative, and formed without the need for interferometry or any moving parts. Wide field-of-view reconstructions of thick biological specimens demonstrate potential applications in pathology and developmental biology.