Space Charge Limits in the Daeδalus DIC Compact Cyclotron

Abstract

The Daeδalus DIC compact cyclotron is proposed to achieve an extracted current of 5 mA of singly-charged hydrogen molecules, even though unlike other compact cyclotrons, the extraction is not by stripping. The authors of the proposal consistently use perveance as a scaling argument that such high current is possible. The argument is shown to be incorrect and a realistic limit is calculated. This limit is likely about 0.2 mA and certainly no higher than 0.5 mA.