Comment on "Large enhancement in high-energy photoionization of Fe XVII and missing continuum plasma opacity"

Abstract

Recent R-matrix calculations claim to produce a significant enhancement in the opacity of Fe XVII due to atomic core excitations [S. N. Nahar & A.K. Pradhan, Phys. Rev. Letters 116, 235003 (2016), arXiv:1606.02731] and assert that this enhancement is consistent with recent measurements of higher-than-predicted iron opacities [J. E. Bailey et al., Nature 517, 56 (2015)]. This comment shows that the standard opacity models which have already been directly compared with experimental data produce photon absorption cross-sections for Fe XVII that are effectively equivalent to (and in fact larger than) the new R-matrix opacities. Thus, the new R-matrix results cannot be expected to significantly impact the existing discrepancies between theory and experiment because they produce neither a "large enhancement" nor account for "missing continuum plasma opacity" relative to standard models.

0

Turn this paper into a lesson

ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.

Discussion (0)

Sign in to join the discussion.

Loading comments…