Evaluating the System Compliance in Testing Carbon Nanotube Fibers
Abstract
System compliances of two testing machines (Keysight T150 and Instron 3365) were studied for the tensile testing of carbon nanotube (CNT) fibers. Due to the different gripping methods, the T150's system compliance was nearly zero, while that of the Instron was nonnegligible. By analyzing the data dispersion with the Weibull theory, a safe gauge length of >10 mm was suggested for CNT fibers. Therefore, a standard test procedure should involve the compliance evaluation, choice of gauge length, and Weibull statistical analysis.
Turn this paper into a lesson