Thermometry of Silicon Nanoparticles
Abstract
Current thermometry techniques lack the spatial resolution required to see the temperature gradients in typical, highly-scaled modern transistors. As a step toward addressing this problem, we have measured the temperature dependence of the volume plasmon energy in silicon nanoparticles from room temperature to 1250, using a chip-style heating sample holder in a scanning transmission electron microscope (STEM) equipped with electron energy loss spectroscopy (EELS). The plasmon energy changes as expected for an electron gas subject to the thermal expansion of silicon. Reversing this reasoning, we find that measurements of the plasmon energy provide an independent measure of the nanoparticle temperature consistent with that of the heater chip's macroscopic heater/thermometer to within the 5\% accuracy of the chip thermometer's calibration. Thus silicon has the potential to provide its own, high-spatial-resolution thermometric readout signal via measurements of its volume plasmon energy. Furthermore, nanoparticles in general can serve as convenient nanothermometers for in situ electron microscopy experiments.
Turn this paper into a lesson
ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.