Sensitivity-bandwidth limit in a multi-mode opto-electro-mechanical transducer
Abstract
An opto--electro--mechanical system formed by a nanomembrane capacitively coupled to an LC resonator and to an optical interferometer has been recently employed for the high--sensitive optical readout of radio frequency (RF) signals [T. Bagci, et~al., Nature 507, 81 (2013)]. Here we propose and experimentally demonstrate how the bandwidth of such kind of transducer can be increased by controlling the interference between two--electromechanical interaction pathways of a two--mode mechanical system. With a proof--of--principle device operating at room temperature, we achieve a sensitivity of 300 nV/Hz(1/2) over a bandwidth of 15 kHz in the presence of radiofrequency noise, and an optimal shot-noise limited sensitivity of 10 nV/Hz(1/2) over a bandwidth of 5 kHz. We discuss strategies for improving the performance of the device, showing that, for the same given sensitivity, a mechanical multi--mode transducer can achieve a bandwidth significantly larger than that of a single-mode one.