Upgrade of the Analog Integrator for EAST Device
Abstract
Integrators are fundamental instruments to recover differential signals from magnetic probes in Experimental Advanced Superconducting Tokamak (EAST) experiments. A kind of difference integrator is introduced which has the same structure as the standard difference amplifier. The linear fitting method is used for determining the effective drift slope, then the plasma control system (PCS) use the drift slope to rectify the integration signal in real time. A new integrator controller was developed, which uses an ARM micro-controller and the lightweight IP protocol stack to realize the network control. The tests show that the upgraded integrator works well, its CMRR is high up to 125 dB when the common voltage is 1.5 V, and the processed integration drift is about 200 uVs /1000 s.
Turn this paper into a lesson
ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.