Measurement of permeability for ferrous metallic plates using a novel lift-off compensation technique on phase signature

Abstract

Lift-off of sensor affects the prediction of electromagnetic properties for both ferrous and non-ferrous steel plates. In this paper, we developed a strategy to address this issue for ferrous plates. With increased lift-off, the phase of the measured impedance for steel plates reduces. Meanwhile, the magnitude of the impedance signal decreases. Based on these facts, a phase compensation algorithm is developed which corrects the phase change due to lift-off considering the magnitude of the impedance signal. Further, a new magnetic permeability prediction technique is presented, which has been validated by analytical and measured results. With this new technique, the error in permeability prediction is less than 2% within the range of lift-offs tested.