Dependable contact related parameter extraction in graphene-metal junctions
Abstract
The accurate extraction and the reliable, repeatable reduction of graphene - metal contact resistance (RC) are still open issues in graphene technology. Here, we demonstrate the importance of following clear protocols when extracting RC using the transfer length method (TLM). We use the example of back-gated graphene TLM structures with nickel contacts, a complementary metal oxide semiconductor compatible metal. The accurate extraction of RC is significantly affected by generally observable Dirac voltage shifts with increasing channel lengths in ambient conditions. RC is generally a function of the carrier density in graphene. Hence, the position of the Fermi level and the gate voltage impact the extraction of RC. Measurements in high vacuum, on the other hand, result in dependable extraction of RC as a function of gate voltage owing to minimal spread in Dirac voltages. We further assess the accurate measurement and extraction of important parameters like contact-end resistance, transfer length, sheet resistance of graphene under the metal contact and specific contact resistivity as a function of the back-gate voltage. The presented methodology has also been applied to devices with gold and copper contacts, with similar conclusions.