Simulated Lorentz Force Detuning Compensation With A Double Lever Tuner On A Dressed ILC/1.3 GHZ Cavity At Room Temperature

Abstract

Pulsed SRF linacs with high accelerating gradients experience large frequency shifts caused by Lorentz force detuning (LFD). A piezoelectric actuator with a resonance control algorithm can maintain the cavity frequency at the nominal level, thus reducing the RF power. This study uses a double lever tuner with a piezoelectric actuator for compensation and another piezoelectric actuator to simulate the effects of the Lorentz force pulse. A double lever tuner has an advantage by increasing the stiffness of the cavity-tuner system, thus reducing the impact of LFD. The tests are conducted at room temperature and with a dressed 1.3 GHz 9-cell cavity.