Quantitative Phase Imaging with a Metalens
Abstract
Quantitative phase imaging (QPI) recovers the exact wavefront of light from the intensity measured by a camera. Topographical maps of translucent microscopic bodies can be extracted from these quantified phase shifts. We demonstrate quantitative phase imaging at the tip of an optical fiber endoscope with a chromatic silicon nitride metalens. Our method leverages spectral multiplexing to recover phase from multiple defocus planes in a single capture. The half millimeter wide metalens shows phase imaging capability with a 280 field of view and 0.1λ sensitivity in experiments with an endoscopic fiber bundle. Since the spectral functionality is encoded directly in the imaging lens, no additional filters are needed. Key limitations in the scaling of a phase imaging system, such as multiple acquisition, interferometric alignment or mechanical scanning are completely mitigated in the proposed scheme