Scheme for quantitative description of longitudinal drifts in the Fermilab Linac and their correction

Abstract

The Fermilab Linac accepts the 0.75 MeV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster. Day-to-day drifts of the longitudinal trajectory in the Linac, reconstructed from phase readings of Beam Position Monitors, are at the level of several degrees. They are believed to cause additional losses both in the Linac and Booster, and are addressed by empirically adjusting the phases of Linac cavities. This work explores the option of expressing these drifts in terms of phase shifts in two cavities at the low-energy part of the Linac. Such a description allows for a simplified visual representation of the drifts, suggests a clear algorithm for their compensation, and provides a tool for estimating efficiency of such compensation.