Frost/Defrost Models for Air-Source Heat Pumps with Retained Water Refreezing Considered

Abstract

Cyclic frosting and defrosting operations constitute a common characteristic of air-source heat pumps in cold climates during winter. Simulation models that can capture simultaneous heat and mass transfer phenomena associated with frost/defrost behaviors and their impact on the overall heat pump system performance are of critical importance to improved controls of heat delivery and frost mitigation. This paper presents a novel frost formulation using an enthalpy method to systematically capture all phase-change behaviors including frost formation and melting, retained water refreezing and melting, and water drainage during cyclic frosting and defrosting operations. A Fuzzy modeling approach is proposed to smoothly switch source terms when evaluating the dynamics of frost and water mediums for numerical robustness. The proposed frost/defrost model is incorporated into a flat-tube outdoor heat exchanger model of an automotive heat pump system model to investigate system responses under cyclic operations of frosting and reverse-cycle defrosting.