Temperature-compensating package for OH line filters for astronomy: II. manufacture, assembly, and performance study

Abstract

Multi-channel aperiodic fiber Bragg grating (FBG) based hydroxyl (OH) line filters have attracted significant interest in ground-based near-infrared (NIR) astronomical observations. In this paper, we present the performance of a new self-compensating enclosure for the filters, that can be used in non-temperature-controlled environments. Our prototype encloses a 110 mm long single-mode photosensitive optical fiber with three 10 mm filter gratings. A fourth grating was used as a reference outside the package to measure the uncompensated wavelength shift. The prototype was tested over three thermal cycles, and showed a maximum wavelength deviation of 12 pm, a wavelength drift of only 0.37 pm/C, over the temperature range of -17C to 15C. The athermalization factor, i.e., the ratio of the maximum wavelength shift of the compensated grating to the uncompensated reference filter grating was 122. The results demonstrate the capability of the prototype for stabilizing multi-channel long-length FBGs or chirped FBGs, particularly for astronomical applications that require sub-picometer stability.

0

Turn this paper into a full lesson

ArcXiv compiles a staged curriculum from this paper: 8-12 lessons across beginner → advanced, synthesised section guides, visuals, flashcards, a quiz, exercises, and on-demand deep dives per section. Grounded in the abstract, never invented.

Discussion (0)

Sign in to join the discussion.

Loading comments…