A bolometric measurement of the antineutrino mass

Abstract

High statistics calorimetric measurements of the beta spectrum of 187Re are being performed with arrays of silver perrhenate crystals operated at low temperature. After a modification of the experimental set-up, which allowed to substantially reduce the background of spurious counts and therefore to increase the sensitivity on the electron antineutrino mass, a new measurement with 10 silver perrhenate microbolometers is running since July 2002. The crystals have masses between 250 and 350 micrograms and their average FWHM energy resolution, constantly monitored by means of fluorescence X-rays, is of 28.3 eV at the beta end-point. The Kurie plot collected during 4485 hours x mg effective running time has an end-point energy of 2466.1 +/- 0.8stat +/- 1.5 syst eV, while the half lifetime of the decay is found to be 43.2 +/- 0.2stat +/- 0.1syst Gy. These values are the most precise obtained so far for 187Re. From the fit of the Kurie plot we can deduce a value for the squared electron antineutrino mass m(nu)2 of 147 +/- 237stat +/- 90syst eV2. The corresponding 90% C.L. upper limit for m(nu) is 21.7 eV.