We present a concept and test results of an eddy-current flowmeter for liquid metals. The flow rate is determined by applying a weak ac magnetic field to a liquid metal flow and measuring the flow-induced phase disturbance in the external electromagnetic field. The phase disturbance is found to be more robust than that of the amplitude used in conventional eddy-current flowmeters. The basic characteristics of this type of flowmeter are analysed using simple theoretical models, where the flow is approximated by a solid body motion. Design of such a flowmeter is presented and its test results reported.