Measurement of the free ion yield and estimate of the electron mobility of Trimethyl-Bismuth (TMBi)This paper investigates the physical characteristics of the liquid Trimethyl-Bismuth (TMBi) relevant for charge readout in potential TMBi filled detectors for Positron-Emission-Tomography (PET)…B. Gerke, V. Hannen, S. Peters et al.·Oct 9, 2026SaveLearn
Beam Spill Structure Measurements at CEE Using the T0 DetectorThe Cooling Storage Ring External-target Experiment (CEE) at the Heavy Ion Research Facility in Lanzhou uses a slow-extracted heavy-ion beam whose temporal profile directly affects detector…Shuaike Lv, D. Hu, Dayu Yin et al.·Oct 9, 2026SaveLearn
CNN-based Position Reconstruction for the T0 Detector in the HIRFL-CSR External-target ExperimentThe T0 detector provides the event start time for the HIRFL-CSR external-target experiment, and its multi-channel readout signals also contain 2D position information of incident particles. In the…Shuai-Ke Lv, D Hu, M Shao et al.·Oct 9, 2026SaveLearn
Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector ReadoutDouble-sided silicon strip detectors (DSSDs) are widely used for charged-particle detection in nuclear reaction experiments. However, the large number of readout channels associated with DSSDs places…Jiawei Bian, Zaihong Yang, Qite Li et al.·Oct 9, 2026SaveLearn
Cavity Characterization for the Princeton Axion SearchThe Princeton Axion Search (PXS) targets the mass window 0.8--2.1~μeV (corresponding to frequencies 200--500~MHz) at DFSZ sensitivity. The experiment, a haloscope,…Nate Otto, Jianyang Fu, Joelle-Marie Begin et al.·Oct 8, 2026SaveLearn
First demonstration of 50\,ps four-dimensional vertex reconstruction with the Timepix4 beam telescopeThe first demonstration of 4D vertex reconstruction at the 50\,ps scale using a silicon pixel detector is reported. Hadronic interactions are produced by directing a 180\,GeV/c…David Bacher, Kazu Akiba, Martin van Beuzekom et al.·Oct 8, 2026SaveLearn
Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26LM26 is a magnetized target fusion experiment built to demonstrate compressional heating of a plasma with a collapsing solid lithium liner. We report the design of a Thomson scattering diagnostic for…P. Carle, S. Edwards, X. Feng et al.·Oct 8, 2026SaveLearn
Autocorrelation-based beam shape optimization in scanning electron microscopyMany automatically focusing algorithms for scanning electron microscopes exist. Typically, these optimize a single derived metric (such as image sharpness) without considering the intrinsic beam…Rebecca Guan, Andreas Werbrouck, Matthew M. Maschmann et al.·Oct 8, 2026SaveLearn
From Tunnel Overburden Reconstruction to Tidal Measurements via atmospheric muonMuography with scintillator-based detectors enables the investigation of density distributions within large structures. The Hankuk Atmospheric-muon Wide Landscaping (HAWL) project is the first…Jiwon Seo, Jongseok Chung, Chang Hyon Ha et al.·Oct 8, 2026SaveLearn
Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localizationMicrometre spatial resolution is achieved for X-rays with the MÖNCH detector, a charge-integrating hybrid pixel detector with a 25 μm pixel pitch, by exploiting charge sharing between neighbouring…Xiangyu Xie, Anna Bergamaschi, Martin Brückner et al.·Oct 8, 2026SaveLearn
Neural network-based timewalk correction for the Timepix4 ASICTimewalk corrections of hybrid pixel detectors conventionally employ heuristic fits performed independently in bins of the relevant input variables. This requires both an explicit functional ansatz…David Bacher, Kazu Akiba, Martin van Beuzekom et al.·Oct 7, 2026SaveLearn
Wavelength-Resolved Timing of Near-Infrared Scintillation in Gaseous XenonThe near-infrared (NIR) scintillation signal of xenon has the potential to enhance the performance of xenon-based detectors, but a robust understanding of its properties is a prerequisite for its…Robert Hammann, Steffen Form, Humaira Nazneen et al.·Oct 7, 2026SaveLearn
Timing Challenges in Transmission Silicon Detectors for Light IonsTransmission silicon detectors are widely used in ΔE--E telescope configurations for particle identification and timing in nuclear physics experiments. Variations in signal rise time can…Diego Tarrio, Friedrich Karl Moraht, Lucas de Arruda et al.·Oct 7, 2026SaveLearn
A Differentiable Surrogate for Loss-Dominated Ion Beam TransportRadioactive nuclei with extreme proton-to-neutron ratios provide unique probes of nuclear structure, fundamental symmetries, astrophysical processes, and applications such as medicine. However, their…Jose M. Munoz-Arias, Laura Ruiz-Arango, Derick Gonzalez-Acevedo et al.·Oct 6, 2026SaveLearn
Omnidirectional Radiation Detector with Perpendicular Dual Silicon Photomultiplier Readout - Directional Sensitivity and Machine Learning Source PositioningDirectional information of incident gamma rays in radiation detection is essential to many applications, from medical imaging to mapping radioactive contamination after nuclear accidents,…Ana Marija Kožuljević, Gabriela Jazvac, Luka Lotina et al.·Oct 6, 2026SaveLearn
GEANT4-Based Comparative Study of Detector Response in Reduced and Fully Instrumented Silicon-Tungsten Sampling CalorimeterA GEANT4-based simulation study of a silicon--tungsten (Si--W) sampling calorimeter is presented to investigate electromagnetic shower development and detector response in the energy range of 1--120…A. Laha, S. Choudhury, S. Muhuri et al.·Oct 6, 2026SaveLearn
The CosmicWatch Desktop Muon Detector (v3X): Prototype Design and Adaptation for SpaceflightThe CosmicWatch Desktop Muon Detector (v3X) is a compact and low-cost scintillator-based instrument designed to detect ionizing radiation, including cosmic-ray muons. Built around a plastic…Anvay Ajmera, Spencer N. G. Axani·Oct 5, 2026SaveLearn
Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation ResponsePlastic scintillators remain attractive for large-area particle detectors because of their fast response, mechanical flexibility, and relatively simple fabrication. Motivated by future applications…Rafael Angel Narcio Laveaga, Ildefonso León Monzón, Juan Carlos Cabanillas Noris et al.·Oct 5, 2026SaveLearn
Expanding Neutron Capacity at the ESS through Symbiotic Instruments: SLEIPNIR & RemoraThe long pulse of the European Spallation Source (ESS) offers unique opportunities to host more than one neutron instrument on a single beam-port. Here, we present two symbiotic instrument concepts…Nicolai Lindaa Amin, Mohamed Aouane, Peter Kjær Willendrup et al.·Oct 5, 2026SaveLearn
Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter ExperimentDirect dark matter detection with NaI(Tl) scintillators requires ultra-low-background materials. Silicone optical pads can couple NaI(Tl) crystals to photomultiplier tubes (PMTs) if they provide…Chemseddine Ananna, Gabriella Cataldi, Davide D'Angelo et al.·Oct 5, 2026SaveLearn
A Cryogenic Geophone with stable response from Room Temperature to millikelvinWith the development of pulse-tube cryocoolers, the availability and use of low-temperature environments have increased exponentially in recent years. However, replacing liquid helium with a…Stefano Pirro, Marco Ricci, Simone Cioccolini·Oct 4, 2026SaveLearn
Application of sequence learning for predicting radiation damage of the CMS electromagnetic calorimeterIn this paper we use machine learning methods to predict radiation damage in the lead tungstate crystals of the CMS electromagnetic calorimeter at the Large Hadron Collider. We analyze LHC Open Data…Mario Ivan Gallegos Torres, Leonid Serkin, Guy Paic·Oct 2, 2026SaveLearn
Controlled-illumination smartphone imaging for quantitative turbidity measurement and cross-device transferSmartphone imaging could provide a low-cost turbidity measurement method if illumination and acquisition geometry are controlled. We evaluated a 3D-printed enclosure with fixed illumination and a…Sebastian Olivares, Addles Castillo, Patricia Velasquez et al.·Oct 2, 2026SaveLearn
Residual AM and PM Noise of Selected X-Band AmplifiersIn microwave systems design, amplitude modulation (AM) noise is often ignored relative to phase modulation (PM) noise. However, in high-performance applications requiring ultra-low PM noise, AM noise…Archita Hati, Craig Nelson, Scott Littrell·Oct 2, 2026SaveLearn
State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future DirectionsIdentifying the particle nature of dark matter remains one of the most significant challenges in modern physics. Direct detection experiments aim to observe rare scattering events between dark matter…Muad Ghaith, Khaled Obaideen·Oct 1, 2026SaveLearn