Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter

Abstract

A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 X0 depth and 180 × 180 mm2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3 mm3 scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be (12.5 0.1 (stat.) 0.4 (syst.))\%/E[GeV] (1.2 0.1(stat.)+0.6-0.7(syst.))\%, where the uncertainties correspond to statistical and systematic sources, respectively.