Cascading Sensor Network Clock Synchronization Scheme

Abstract

In this paper, we propose a hybrid clock synchronization architecture for a cascaded sensor network based on GPS time service and synchronous frame protocol. The sensor's upper-level unit is called sensor management unit (SMU) which synchronizes the local clock with the GPS and then use the broadcast sync frame to synchronize the clock of the sensor chain. In this paper, we build a link of 20 cascaded sensors to measure the center frequency and clock stability. The results showed that the center frequency deviation was 0.037 Hz and the stability was 0.045 ppm to 0.066 ppm .The stability of GPS is 0.06ppm, the scheme has achieved the effect similar to installing GPS chip on every sensor.

0

Turn this paper into a lesson

ArcXiv compiles a structured reading guide from this paper's metadata: plain-English importance, contributions, prerequisite concepts, which sections to read first, flashcards, and a quiz. Grounded in the abstract, never invented.