Simultaneous measurement of the light and charge response of liquid xenon to low-energy nuclear recoils at multiple electric fields

Abstract

Dual-phase liquid xenon (LXe) detectors lead the direct search for particle dark matter. Understanding the signal production process of nuclear recoils in LXe is essential for the interpretation of LXe based dark matter searches. Up to now, only two experiments have simultaneously measured both the light and charge yield at different electric fields, neither of which attempted to evaluate the processes leading to light and charge production. In this letter, results from a neutron calibration of liquid xenon with simultaneous light and charge detection are presented for energies from 3-74 keV, at electric fields of 0.19, 0.49, and 1.02 kV/cm. No significant field dependence of the yields is observed.