Abstract

The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The signals from the Micromegas readout are processed by a data acquisition system based on the General Electronics for TPC (GET). The drift chamber has an effective area of around 60x30 cm2, which matches to the very large acceptance of the S800 spectrometer. This work discusses in detail the results of performance evaluation tests carried out with a low-energy alpha-particles source and with high-energy heavy-ion beams with the detector installed at the S800 focal plane. In this latter case, the detector was irradiated with a 150 MeV/u 78Kr36+ beam as well as a heavy-ion fragmentation cocktail beam produced by the 78Kr36+ beam impinging on a thin beryllium target. Sub-millimeter position resolution is obtained in both dispersive and non-dispersive directions.