Taiwan Axion Search Experiment with Haloscope: Designs and operations

Abstract

We report on a holoscope axion search experiment near 19.6\ μ eV from the TASEH collaboration. The experiment is carried out via a frequency-tunable cavity detector with a volume V = 0.234\ liter in a magnetic field B0 = 8\ T. With a signal receiver that has a system noise temperature T sys 2.2\ K and experiment time about 1 month, the search excludes values of the axion-photon coupling constant g aγγ 8.1 × 10-14 \ GeV-1, a factor of 11 above the KSVZ model, at the 95\% confidence level in the mass range of 19.4687-19.8436\ μ eV. We present the experimental setup and procedures to accomplish this search.