CANDOR: Chance-Calibrated Neighborhood Discordance in Frozen Encoders for Medical Imaging
Abstract
In medical imaging, one frozen foundation encoder is often reused for many tasks. The encoder is usually chosen by the area under the receiver operating characteristic curve (AUROC) of a head trained on its features. The AUROC does not measure whether the encoder separates positive from negative images in its feature space. Chance-calibrated neighborhood discordance (CANDOR) measures this separation without training a head. Among images acquired the same way, a positive image is discordant when its k nearest negatives are more similar to it on average than its k nearest positives are. The discordance rate D is the share of discordant positives. When the neighbors come from positive and negative candidate sets of equal size, D has the chance level 1/2 for features without information about the label. With unequal candidate sets, all 11 chest encoders have rates above 1/2 (0.732 to 0.927) on the 12 chest findings of MIMIC-CXR and CheXpert. These rates increase as the finding becomes rarer. With equal sets, the same encoders have rates below 1/2 (0.277 to 0.463). On the chest test split, linear heads miss 0.301 of the discordant positives and 0.165 of the other positives. Across 22 encoders, 605,443 images, and 8 tasks in 7 domains, the best encoder of every task has a rate below 1/2. Because computing D takes one forward pass per image, a hospital can compare candidate encoders before it trains any head.
Create a lesson
Metadata
- Categories
- cs.LG, cs.AI, cs.CL, cs.CV
Related papers
Can image generation help visual reasoning? An empirical study
Shared title terminologycs.LGXueyang Yu, Yifan Jing, Taiming Lu et al.
Privileged On-Policy Distillation for Calibrated Alzheimer's Diagnosis With Missing Modalities
Shared title terminologycs.LGVo Minh Khoi Nguyen, Dat Tien Chung, Quang Minh Khoa Le et al.
RAWPrism: A Three-Task Dataset and a Unified Model for RAW-Domain Image Fusion
Shared title terminologycs.LGTianyi Hu, Yangdong Li, Shuyan Liu et al.
Train-Only-Constrained LM for Synthetic Clinical Trajectories: Leak-Safe Calibration and Auditable Dynamics
Shared title terminologycs.LGYaser Kord, Moritz Hess
MUSE: Multi-Task Uncertainty-Aware Self-Supervised Encoder for mmWave ISAC
Shared title terminologycs.LGNabeel Nisar Bhat, Jalees Nehvi, Rafael Berkvens et al.
CondUQ: Calibrated Conditional Uncertainty Quantification Using Distribution Matching
Shared title terminologycs.LGShizhuang Wang, Tianhao Wang, Xingqun Zhan