HARMONI at ELT: LPOU calibrations for a micron-level pointing accuracy
Gonzalo José Carracedo Carballal, Irene Ferro Rodríguez, David L King, Iago Funes Vecino, Guillermo Mercant Rubio, Alonso Álvarez Urueña, Laura García Moreno, Heribert Argelaguet Vilaseca, Javier Piqueras López, Chiara Cerruti
Abstract
HARMONI is the first light, adaptive optics assisted, near-IR integral field spectrograph for the ELT [1]. It covers a spectral range from 800 nm to 2450 nm with resolving powers from 3000 to 7000 and spatial sampling of 25 mas and 6mas. It can operate in two adaptive optics modes, SCAO (including a high contrast capability) and MCAO. The project is resuming its final design phase after a rescope design phase in 2025. To achieve its optimal image quality, HARMONI needs to perform pointing error measurement by means of three guide probes. Each guide probe is a robotic arm with a shoulder-elbow stage that is optically equivalent to two periscopes connected together. Since any systematic positioning error of the shoulder-elbow motors will result in a measurement error of the pointing error itself, an appropriate geometric calibration reference is necessary. In previous designs, this calibration reference took the form of a deployable calibration mask that could be inserted in the telescope's focal plane. However, this approach prevents the guiding sensors from distinguishing motor contributions from other effects caused by the instrument optics. In this work, we explore the possibility of inserting the calibration mask as close to the guide probes as possible, along with the addition of the necessary refocus optics in the light path of the guiding sensors. We discuss different variations of this idea, their effect on the image quality, and their ability to resolve positioning errors smaller than 1 μm. The results of these analyses were cross-validated by means of optical simulations in RayZaler, and will be used to put bounds to the expected calibration accuracy achievable by this design.
Create a lesson
Metadata
- Comments
- 7 pages, 8 figures
Related papers
UNIONS and Euclid: Calibrating point source-galaxy separation for ground-based surveys
Shared title terminologyastro-ph.IMG. Thomas, S. E. T. Smith, S. Gwyn et al.
RIFT for the O4 era: operating points, calibration marginalization, and cross-code validation
Shared title terminologyastro-ph.IMR. O'Shaughnessy, A. Jan, J. Lange et al.
Improved accuracy of the reference photon calibration standards in the network of gravitational-wave observatories during the O4 observing run
Shared title terminologyastro-ph.IMDripta Bhattacharjee, Cervane Grimaud, Matthew Spidell et al.
Pixel-Level Calibration for Space-Based High Precision Astrometry Using Young's Fringes
Shared title terminologyastro-ph.IMHugo Rousset, Eric Thiébaut, Chloé Rey et al.
A data-driven absolute amplitude calibration for the Radio Neutrino Observatory Greenland (RNO-G)
Shared title terminologyastro-ph.IMG Collaboration, Sanyukta Agarwal, Juan Antonio Aguilar et al.
A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction Encoding
Shared title terminologyastro-ph.IMDillon J. Bass, Bradley R. Johnson