MRI-guided cardiac radiotherapy using a 1.5 T MR-linac: surveying emerging patterns of care
O. Akdag, S. Mandija, J. Pomp, M. P. W. Intven, X. Chen, J. Yang, S. Oh, M. Trombetta, H. Tan, J. De Leon, M. Jameson, E. Efe, C. Önal, M. F. Fast
Abstract
Background: Cardiac tumours are rare and treated by surgical resections, which are complex, invasive and carry procedural risks. MRI-guided radiotherapy (MRgRT) noninvasively facilitates conformal dose deliveries using soft-tissue imaging and adaptive radiotherapy techniques. Aim: To assess the application of MRgRT for cardiac tumours, we conducted a patterns-of-care analysis with users of the 1.5T MR-linac. Materials & methods: A survey was distributed to users of the 1.5T MR-linac that treated patients with cardiac tumours. The survey included 30 questions concerning the patient cohort, imaging, treatment planning/simulation, radiotherapy treatment and treatment outcome. Results: Users from six international institutes completed the survey reporting twelve cardiac MRgRT treatments between 2021-2024. The median age[range] of the patients was 59[16-81] years with 50% of the cases concerning the treatment of primary tumours. The prescribed dose ranged between 30-60 Gy, with 30 Gy being prescribed the most (59%). In 75% of the cases, the treatment plans were delivered in five fractions with 6-8 Gy per fraction. Daily images were acquired with T1- and T2-weighted MRI and respiratory motion monitoring was performed in 92% of the cases using cine imaging. A single case was treated with intrafraction motion management using a novel vendor-provided gating solution on the MR-linac. Treatment outcomes were reported for 50% of the cases. All, but one case, attained local control using MRgRT without serious adverse events (grade≥3). Conclusion: This study provides real-world insights into the feasibility and early outcomes to aid the development of cardiac MRgRT treatment recommendations and protocol harmonization.
Create a lesson
Related papers
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler et al.
Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
Michael Douglass, Corey Bridger, Mitchell Herrick et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al.
Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
Yuntao Wang
The Electrodynamic Basis of Dichroism-Mediated Polarization Perception
Gary P. Misson, Dusan Sarenac, Dmitry. A. Pushin et al.