LV-CARE-Diff: A Conditional Anatomy-Aware Diffusion Model for Left Ventricular Shape Reconstruction and Function Quantification from Ultra-Sparse Cine Slices
Xinwang Li, Yu Lian, Bowei Liu, Yifei Jiang, Jingjing Xiao, Haiyan Ding, Xiangchuang Kong, Rui Guo
Abstract
Left ventricular functional quantification is an essential examination and is routinely performed using cardiovascular magnetic resonance (CMR) cine imaging. However, conventional CMR cine protocols require the acquisition of multiple short-axis (SAX) slices to cover the entire left ventricle (LV) along with two long-axis (LAX) slices, which is time-consuming and places a considerable burden on patients who are unable to sustain repeated breath-holds, limiting its suitability for large-scale early screening. In this study, a Conditional Anatomy-Aware Diffusion Model (LV-CARE-Diff) was developed using a coarse-to-fine strategy to reconstruct the complete LV shape from ultra-sparse cine slices, namely three short-axis and two long-axis slices, with the aim of accelerating CMR cine examination. LV-CARE-Diff employs a 3DUNet to generate a coarse initial shape, which is subsequently refined through a residual diffusion model. A condition-guided input incorporating imaging plane orientation and positional metadata was constructed to enable spatial awareness, and a multi-objective training strategy jointly supervising shape, function, and anatomy was incorporated to guide high-fidelity reconstruction. LV-CARE-Diff was compared against a standalone 3DUNet, a standalone diffusion model, and a 3D UNet with diffusion-based refinement. Testing results indicated that complete LV shape could be robustly reconstructed by all deep learning models, with the highest reconstruction performance achieved by the proposed LV-CARE-Diff. Deep learning models reconstructing LV shape from sparse cine slices preserved 96% of functional quantification accuracy while reducing imaging time by 73%. The LV-CARE-Diff framework established in this study enables ultra-sparse cine acquisition to shorten CMR examination duration without sacrificing quantitative functional accuracy.
Create a lesson
Related papers
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler et al.
Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
Michael Douglass, Corey Bridger, Mitchell Herrick et al.
Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez et al.
Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
Louis-Bernard St-Cyr, Anne Saint-Laurent, José Angel Lesteiro-Tejeda et al.
Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
Yuntao Wang
The Electrodynamic Basis of Dichroism-Mediated Polarization Perception
Gary P. Misson, Dusan Sarenac, Dmitry. A. Pushin et al.