Design optimization, commissioning, and uncertainty analysis of the quadrupole resonator system at Jefferson Lab for SRF material characterization
Mingqi Ge, Sarra Bira, Kristof Brunner, Natalie Gale, Marco Garlasche, Valentin Giglia, Oleksandr Hryhorenko, Justin Kent, Peter Owen, Uttar Pudasaini, Guillaume Rosaz, Karol Scibor, Pramita Tiwari, Anne-Marie Valente-Feliciano, Lorena Vega Cid, Walter Venturini, Haipeng Wang
Abstract
A quadrupole resonator (QPR) provides a sample-based platform for characterizing materials for superconducting radio-frequency (SRF) applications under controlled field, frequency, and temperature conditions. This paper presents the design optimization, commissioning, and validation of the Jefferson Lab QPR system, including a quantitative assessment of measurement uncertainty. The resonator geometry was re-optimized from the CERN version-II design to improve quadrupole-mode separation and enable four usable modes at 400, 806, 1221, and 1640 MHz. The measurement system combines self-excited-loop RF operation, cable-loss-corrected power calibration, decay-based external-Q calibration, and RF-DC thermal-substitution calorimetry to determine the peak surface magnetic field Bpk and sample surface resistance Rs. Commissioning measurements on bulk Nb and Nb3Sn-Ta-Cu samples validated the system response over a broad range of frequency, temperature, and RF field. The extracted superconducting energy-gap parameters are consistent with the reported values for Nb and Nb3Sn, as well as with those obtained from single-cell cavity measurements. The commissioned system operates from 1.8 K to near the superconducting transition temperature of the sample, with accessible Bpk values from approximately 5 mT to a sample- and temperature-dependent heater-power-budget limit; a maximum field of 60 mT was demonstrated for bulk Nb at 400 MHz and 4 K. The combined relative standard uncertainties are 8.3% for Bpk and below 18% for Rs when r = PDC2/PDC1 is less than 0.9. The worst-case Bpk resolution at the 95% confidence level is approximately 1.35 mT, while the Rs resolution is below 1 nOhm at 10 mT and 2 K. These results establish the JLab QPR as a calibrated, multi-frequency platform with quantified measurement uncertainty for SRF material characterization.
Create a lesson
Related papers
Equivalent-circuit analysis of the transverse resonant beam coupling impedance due to ceramic-chamber RF shields in the J-PARC Main Ring spill-feedback quadrupoles
Shared title terminology · Masahito Tomizawa
An Analytical Model for Fast Design Optimization and Performance Studies of nuSTORM
Shared title terminology · ESSnuSB Collaboration, T. W. Choi, M. Olvegård et al.
Optimizing an RFSoC LLRF Controller for a Low-PRF, Short Pulse System
Shared title terminology · Victoria Moore, Qiang Du, Shreeharshini Murthy et al.
Design and optimization of the NSLS-II lattice with complex bend replacement
Shared title terminology · Minghao Song, Yoshiteru Hidaka, Bernard Kosciuk et al.
Preliminary design of continuous wave Low-Level RF systems for S3FEL
Shared title terminology · Z. Y. Zhang, J. F. Zhu, H. L. Ding et al.
Low Level RF and Timing System Design for the Cool Copper Collider
Shared title terminology · Chao Liu, Ankur Dhar, Martin Breidenbach et al.