Abstract
Proximal shunt obstruction is the leading cause of ventriculoperitoneal (VP) shunt failure in pediatric hydrocephalus and is closely tied to the near-wall shear environment at drainage holes. We used computational fluid dynamics (COMSOL) to decouple local wall-shear-stress (WSS) control via catheter-tip geometry from global drainage control via a valve opening. A cylindrical ventricle domain with Newtonian CSF ( = 1000 kg/m, = 1 mPas) and 10 mmHg was solved under laminar Navier-Stokes flow while sweeping distal hole spacing, hole count/diameter, and a simplified valve constriction. Mesh-independence was achieved (minimum element size 0.021 mm; distal-hole velocity converged to 1.18 m/s). Perpendicular separation of the two most distal holes increased total outflow by 22% (2 mm vs 0.5 mm) and raised distal lateral-wall WSS by 19%, whereas longitudinal shifts of upstream holes produced only small changes. A valve opening near 0.166-0.17 mm set system drainage to 20 mL/h across geometries, indicating capacity is valve-limited while local WSS is geometry-controlled. The selected tip uses two conical holes (0.5 mm ID) in four rows with 1.4 mm spacing, concentrating WSS at the distal lateral walls, the surfaces where obstruction occurs, without exceeding clinical drainage targets. These findings yield design rules: prioritize distal-pair spacing, reduce hole count with smaller conical openings to elevate protective WSS, and regulate outflow with the valve. The framework provides a clear path to benchtop validation, long-term adhesion assays under mapped WSS, and anatomically realistic CFD.
Create a lesson
Related papers
Dynamic infrared thermography and computed tomography angiography fusion for DIEP flap perforator selection: a novel measurement system
Shared title terminologyphysics.med-phWarre Clarys, Roanne Van Steen, Simon Verspeek et al.
A Computational Journey Toward an Optimal Design for Metamaterial Epicardial Passive Sleeves
Shared title terminologyphysics.med-phVahid Naeini, Emilio A. Mendiola, Ahmad Rafsanjani et al.
High-Resolution 3D Micro-CT Database of Transcranial Magnetic Stimulation (TMS) Coils for More Accurate Modelling, Technology Benchmarking, and Progress in Coil Design
Shared title terminologyphysics.med-phMaryam Farahmandrad, Max Koehler, Mahdi Bayati et al.
Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR Brachytherapy
Shared title terminologyphysics.med-phKevin Willy, Megan Clark, Petr Bruza et al.
A High-Fidelity Cardiac Digital Twin for Assessing Rate-Dependent Responses: A Comparative Multi-scale Study of TT2 and Tomek Models in Stratified 3D Ventricles
Shared title terminologyphysics.med-phZhenyin Fu, Zhaokai Kong, Lucheng Xu et al.
Bayesian Kinetic Model Selection in Dynamic PET via Consistency Models
Shared title terminologyphysics.med-phYun Zhao, Qinlin Gu, Andrew J. Reader et al.