Skip to content

Demonstrating topological identification capabilities of the NEXT experiment at low pressure

J. Waiton, H. Almazán, B. Palmeiro, G. Martínez-Lema, R. Guenette, V. Álvarez, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C. D. R. Azevedo, F. Ballester, J. E. Barcelon, M. del Barrio-Torregrosa, J. M. Benlloch-Rodríguez, F. I. G. M. Borges, A. Brodoline, C. Cabo, A. Castillo, E. Church, M. Cid, X. Cid, C. A. N. Conde, C. Cortes-Parra, F. P. Cossío, R. Coupe, E. Dey, P. Dietz, C. Echeverria, M. Elorza, R. Esteve, R. Felkai, L. M. P. Fernandes, P. Ferrario, P. Ferrero Mancheño, F. W. Foss, Z. Freixa, J. García-Barrena, J. J. Gómez-Cadenas, J. W. R. Grocott, J. Hauptman, C. A. O. Henriques, J. A. Hernando Morata, P. Herrero-Gómez, V. Herrero, C. Hervés Carrete, Y. Ifergan, A. F. B. Isabel, B. J. P. Jones, F. Kellerer, L. Larizgoitia, A. Larumbe, P. Lebrun, F. Lopez, N. López-March, R. Madigan, R. D. P. Mano, A. Marauri, A. P. Marques, J. Martín-Albo, A. Martínez, M. Martínez-Vara, R. L. Miller, K. Mistry, J. Molina-Canteras, F. Monrabal, C. M. B. Monteiro, F. J. Mora, K. E. Navarro, P. Novella, D. R. Nygren, E. Oblak, I. Osborne, J. Palacio, A. Para, A. Pazos, J. Pelegrin, M. Pérez Maneiro, M. Querol, J. Renner, I. Rivilla, C. Rogero, L. Rogers, B. Romeo, C. Romo-Luque, E. Ruiz-Chóliz, P. Saharia, F. P. Santos, J. M. F. dos Santos, M. Seemann, I. Shomroni, A. L. M. Silva, P. A. O. C. Silva, A. Simón, S. R. Soleti, M. Sorel, J. Soto-Oton, J. M. R. Teixeira, S. Teruel-Pardo, J. F. Toledo, C. Tonnelé, S. Torelli, J. Torrent, A. Trettin, P. R. G. Valle, M. Vanga, P. Vázquez Cabaleiro, J. F. C. A. Veloso, J. D. Villamil, L. M. Villar Padruno, A. Yubero-Navarro

hep-ex

Abstract

The NEXT-100 detector is a high-pressure xenon time projection chamber utilising electroluminescence amplification for sub-1% FWHM energy resolution and topological discrimination, two key attributes required to achieve the NEXT programme's overarching goal of detecting neutrinoless double beta decay (0νββ0 νββ). The detector has completed its first physics run at the Laboratorio Subterráneo de Canfranc (LSC), with xenon at a pressure of ∼\sim4 bar. In this paper we report on the first validation of NEXT-100's topological performance and present the first topological analysis conducted at low pressure within the detector programme. A Monte Carlo study characterising the effects of pressure on track topology is presented, with qualitative agreement observed in data. We then demonstrate the topological discrimination capabilities for 0νββ0νββ-like events from 208^{208}Tl decays using a cut-based method considered the 'baseline' in NEXT's topological programme, upon which all future analyses will improve. The analysis described applies a set of selection cuts before implementing a background discrimination algorithm that yields a reported signal efficiency for double-electron tracks and background acceptance for single-electron tracks of 75.6 ±\pm 1.9 (stat.) −4.1+3.4^{+3.4}_{-4.1} (syst.) % and 14.7 ±\pm 0.4 (stat.) −0.8+0.7^{+0.7}_{-0.8} (syst.) %. These results demonstrate the excellent topological discrimination capabilities of the NEXT-100 detector in line with NEXT-White, which achieved a signal efficiency and background acceptance of 71.6 ±\pm 1.5 (stat.) ±\pm 0.3 (syst.) % and 20.6 ±\pm 0.4 (stat.) ±\pm 0.3 (syst.) % respectively.

Create a lesson

Metadata

Comments
14 pages, 6 appendix + references