ModaLens: Measuring Image Sensitivity in Report-Conditioned Medical VLMs
Sebastián Andrés Cajas Ordóñez, Maximin Lange, Quang Bui, Anqi Peter Li, Felipe Ocampo Osorio, Rafi Al Attrach, Kushul Reddy Palakala, Sahil Kapadia, Zakaria Laouabdia Sellami, Xinyue Zhang, Ashley Zhang, Leo Anthony Celi
Abstract
A radiology report can already answer a clinical question, so it is hard to tell whether a vision-language model also uses the image. ModaLens, a paired image-swap audit, measures how report availability changes image sensitivity: MedGemma-27B on 3,199 paired MIMIC-CXR cases from 293 patients, all 14 questions per case (13 finding-specific and one composite), each image replaced by one from another study, usually of the same patient, with question and report fixed. Under an explicit answer instruction, the model's generated answer changes on 4.26 percent of trials with the report and 20.94 percent without it, a paired increase of 16.7 points (patient-clustered 95 percent CI 15.6 to 17.7), so report availability reduces image-swap sensitivity under this protocol; the original prompt with a lowercase first-token readout gives 4.70 percent against 17.07 percent, and substitutions also move continuous answer scores where the binary prediction does not change. The labels are derived from reports, which limits conclusions about visual correctness; the direction replicates in two further model lineages. Code, the exact prompts and a run record for every number are at https://github.com/criticaldata/MODALENS.
Create a lesson
Metadata
- Categories
- cs.CV, cs.AI
Related papers
MUMINS: Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis
Shared title terminologycs.CVAnna Oliveras, Roger Marí, Rafael Redondo et al.
Physics-Guided Generative Modelling of Oxy-Combustion Flame Images: From Conditional LSGANs to Denoising Diffusion Models
Shared title terminologycs.CVImane Er-rabhi, Gorkem Oztarlik, Jean Caudal et al.
GazeDiT: Gaze-Accurate Diffusion Image Generation for Eye Tracking via Spatial Conditioning
Shared title terminologycs.CVDongze Wu, David Colmenares, Fengting Yang et al.
De-GAN - Dynamic Parameter Tuned GAN for 3D Medical Image Segmentation: A Step Towards Generalisation
Shared title terminologycs.CVZoha Usama, Azadeh Alavi
Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy
Shared title terminologycs.CVJiale Shen, Guolin Wang, Chenhao Wang et al.
High-Fidelity Image Matting with Pixel-Space Diffusion Transformers
Shared title terminologycs.CVBaihan Yang, Xin Lin, Yufan Wei et al.