Skip to content

1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor

M. L. Roukes

cond-mat.mes-hall

Abstract

Mechanical frequency-shift sensors have never reached the resolution their thermomechanical or quantum limits predict: a 1/f1/f frequency-noise floor keeps them 1-4 orders short of it. Across the published record, the product of the floor's flicker coefficient h−1h_{-1} and the strain-weighted resonator volume, VεV_{\varepsilon}, is size-independent over 13 decades. It is also independent of measured QQ; I find that QQ-volume covariance underlies reported QQ-dependence. It is defect density that imposes the frequency-noise floor: prestress can dilute it, but only in fixed-end devices. Mass resolution follows as ∣δm∣∝V|δm|\propto\sqrt{V}.

Create a lesson

Metadata

Categories
cond-mat.mes-hall, quant-ph
Comments
9 pages, 3 figures, Supplemental Material also provided - Revision R2