Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study
Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon, Jost B. Jonas, Ya Xing Wang, Vinay Nangia, Jin Wook Jeoung, Sehie Park, SoYeon Kim, Benjamin Y Xu, Sreenidhi Iyengar Munimadugu, Paul Mitchell, Gerald Liew, Yanin Suwan, Jirayu Hong-amata, Sahil Thakur, Monisha E Nongipur, Tina Wong, Rahat Husain, Ng Si Rui, Yamon Syn, Phey Feng Lo, Nicholas Tan Yi Qiang, Shaista Hussain, Xiaofeng Lei, Zhi Da Soh, Marco Yu, Haslina Hamzah, Zizhou Wang, Yan Wang, Liangli Zhen, Xinxing Xu, Tien-Yin Wong, Tin Aung, Rachel S Chong, Yong Liu, Ching-Yu Cheng
Abstract
Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.
Create a lesson
Metadata
- Categories
- cs.CV, cs.AI
Related papers
Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation
Shared title terminologycs.CVJanhavi Prabhu, Sahil, Akshay V et al.
Not All Confusion Is Equal: A Source-Aware Uncertainty Diagnosis for Fine-Grained Aircraft Detection
Shared title terminologycs.CVHai Huang, Helmut Mayer
Focus Only on What's Important: Training-Free Focus Maps for Frozen Vision Transformers in Long-Video Object Segmentation
Shared title terminologycs.CVHarsha Karipineni, Rajesh Reddy Chintha
Recalling the Past to Answer the Present: Context-Aware Multi-Evidence Reasoning for Streaming Video Question Answering
Shared title terminologycs.CVCui Yakun, Tiantian Geng, Huixiang Kong et al.
Devol-ONE: One Autoregressive Mixture of Transformers to Unify Vision-Language-Action and Latent World Modeling
Shared title terminologycs.CVHongyi Cai, Yi Herng Ong, Tingshiuan C. Wu et al.
PQR3D: Progressive Query Refinement over Reference-Conditioned Temporal Windows for Multi-View 3D Object Detection
Shared title terminologycs.CVHui Ye, Yudong Liu, Yiran Chen et al.