When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation
Emmanuel Idoko, Abdusshakur Olabisi, Shiloh Oni, Adesola Josiah
Abstract
Retrieval-augmented generation is an attractive way to improve chest X-ray reporting, because reports from similar prior studies supply clinical context a general vision-language model lacks. We show the same mechanism is a reliable source of clinical error. Over 100 MIMIC-CXR studies with a frozen LLaVA-1.5 generator and BioMedCLIP retrieval, CheXbert clinical F1 doubles under relevant retrieval (0.201 to 0.402) and collapses to 0.043 under clinically mismatched retrieval, a fifth of the image-only score; the retrieval-induced hallucination rate, counting only unsupported findings traceable to retrieved evidence, rises from 0.00 to 0.76 and 0.98. To show this is not an artefact of evidence-set coverage, we introduce a coincidental-overlap control that scores image-only generations against evidence they never saw, placing the chance base rate at 0.18, four to five times below the observed rates. The generator does not merely acquire findings, it transcribes text: 95% of reports produced under relevant retrieval contain an eight-word span occurring verbatim in the retrieved evidence but absent from the reference, against 0% without retrieval. We then explain the mechanism: a normal chest X-ray retrieves at least one abnormal precedent in 24 of 28 cases, because medical image-embedding similarity is dominated by anatomy and acquisition rather than by the presence of disease. This has a direct design consequence. Retrieval similarity does not predict harm (RIH rates 0.80/0.80/0.60/0.84 across similarity quartiles), so relevance gates conditioned on embedding similarity cannot work; gating on predicted pathology agreement removes 61% of unsupported evidence at no cost to useful coverage. We argue that retrieval-augmented clinical systems must be evaluated under retrieval failure, not only under retrieval success.
Create a lesson
Metadata
- Comments
- 10 pages, 4 tables
Related papers
Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset
Shared title terminologycs.CVXiao Wang, Yuxiang Zhang, Dan Xu et al.
Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation
Shared title terminologycs.CVJanhavi Prabhu, Sahil, Akshay V et al.
Fysiverse-3D-Vision Technical Report: Generating Executable 3D Worlds from Images through Unified Spatial Reasoning
Shared title terminologycs.CVDingkang Yang, Yizhou Liu, Wendong Cheng et al.
AnyCam: Anything Can Represent Camera for Video Generation
Shared title terminologycs.CVWeijie Lyu, Zhixin Shu, Yuntian Ke et al.
Agentic LongLive: Asynchronous Agentic Memory for Long Video Generation
Shared title terminologycs.CVShaoteng Liu, Shuai Yang, Wei Huang et al.
Generation as Reverse Encoding
Shared title terminologycs.CVCheng Shi, Sibei Yang, Hanzhong Guo et al.