The Simons Observatory: Design and Initial Performance of the Detector Readout System for the Large-Aperture Telescope
Thomas P. Satterthwaite, Tristan Pinsonneault-Marotte, Shawn W. Henderson, Zeeshan Ahmed, Kam Arnold, Declan Baker, Andrew Bazarko, Josh Borrow, Michael L. Brown, Mark Devlin, Simon Dicker, Peter N. Dow, Shannon M. Duff, Daniel Dutcher, John C. Groh, Saianeesh K. Haridas, Kathleen Harrington, Erin Healy, Johannes Hubmayr, Bradley R. Johnson, Brian Keating, Anna M. Kofman, Adrian T. Lee, Alex Manduca, Aashrita Mangu, Jenna E. Moore, Michael D. Niemack, Sandra O'Neill, John Orlowski-Scherer, Yudai Seino, Mufan Shao, Carlos Sierra, Max Silva-Feaver, Suzanne Staggs, Eve M. Vavagiakis, Yuhan Wang, Edward J. Wollack
Abstract
We present the design, implementation, and initial performance of a highly multiplexed cryogenic superconducting detector readout system in the context of its deployment to the Simons Observatory large-aperture telescope (LAT). The Simons Observatory is a cosmic microwave background experiment located at 5,200 m in Chile's Atacama Desert. In addition to its 6 m LAT, whose broad range of science goals spans probing large-scale structure to searching for new Solar System objects, the observatory also currently includes three 0.42 m small-aperture telescopes, which search for signatures of primordial gravitational waves. Nearly 100,000 optically-coupled transition-edge sensor bolometers have been deployed across the observatory's four telescopes to enable these science goals. The readout systems for these telescopes use microwave frequency multiplexing to simultaneously read out 860 optically-coupled bolometers per transmission line. This is enabled by the large-scale fabrication of multiplexing chips which house radio-frequency superconducting quantum interference devices for each detector, and the development of room-temperature electronics to read out these bolometers. This has enabled the largest deployment of superconducting sensors for astronomical observations to date. This paper focuses on the design and implementation of the readout system for the 63,000 detectors in the LAT's cryogenic receiver. We present performance results from an early phase in the telescope's operation. We show that the readout system's performance enables the instrument to meet key benchmarks, including successful readout of 81.4% of its optically-coupled bolometers, which exceeds projections, and readout noise-equivalent current consistent with pre-deployment specifications.
Create a lesson
Related papers
The Simons Observatory: Commissioning of the Mid-Frequency Small Aperture Telescopes
Shared title terminology · Kathleen Harrington, Remington Gerras, Nicholas Galitzki et al.
A Large-Scale Technosignature Survey of the Anti-Solar Point with the Allen Telescope Array: Survey Design and Pilot Results
Shared title terminology · Sofia Z. Sheikh, Eleanor Hort, Bárbara Cabrales et al.
Optimal Design of Shaped Pupil Lyot Coronagraph for China's Large Segmented Telescope
Shared title terminology · Kaining Yang, He Sun, Bin B. Ren et al.
Investigation of magnetic-field effects on photomultiplier tubes for the first Large-Sized Telescope of the Cherenkov Telescope Array Observatory
Shared title terminology · Yukiho Kobayashi, Dai Tateishi, Yuji Sunada et al.
Inertial sub-range detection and characterization for ground-layer turbulence at new extremely large telescope sites in Chile
Shared title terminology · Marco Sepúlveda, Darío G. Pérez
Adaptive Optics for the Extremely Large Telescope: overcoming Point Spread Function challenges with MORFEO
Shared title terminology · Carmelo Arcidiacono, Elisa Portaluri, Marco Gullieuszik et al.