Skip to content

When voltage sensors fail: Electrochemically constrained fault-tolerant state estimation for flat-plateau LFP batteries

Feng Guo, Luis D. Couto, Hamid Hamed, Khiem Trad, Dong Zhang, Ru Hong, Guangdi Hu, Mohammadhosein Safari

eess.SY

Abstract

The flat voltage plateau of lithium iron phosphate (LFP)/graphite cells makes electrochemical-state errors and voltage-measurement abnormalities produce similar innovations, complicating state-of-charge (SOC) estimation. This work proposes an electrochemically constrained residual-bias compensation dual extended Kalman filter (RBC-DEKF) with uncertain-initialization commissioning. A thermal control-oriented parameter-grouped single-particle model (CPG-SPMT) provides paired-electrode dynamics and terminal-voltage prediction, while a separately configurable voltage-discrepancy state accommodates systematic residuals. When the initial SOC is uncertain, residual adaptation is suspended over a verified-healthy startup window. Buffered data support electrochemically constrained trajectory matching, followed by calibrated state replay and residual-channel reactivation. Frozen cross-cycle healthy-residual calibration supports commissioning and remains in the voltage prediction after handover. Evaluation covers 216 additive-bias and 168 multiplicative-gain profiles over 24 A123 temperature-drive-cycle trajectories. Relative to Single-EKF, the original RBC-DEKF reduces mean SOC RMSE from 7.646 to 0.170 percentage points for additive bias and from 22.646 to 0.356 percentage points for gain faults. Separately, 18 nonzero-initial-error profiles on three representative 50%-SOC-anchored segments give a full-record mean SOC RMSE of 1.747 percentage points, including startup, for the commissioned realization, versus 11.192 and 11.400 for the always-on RBC-DEKF and conventional joint EKF. Representative delayed bias, 10-s ramp, and gain tests show that the corrected SOC trajectory remains stable after fault introduction. The central contribution is electrochemically constrained temporal coordination of uncertain-state recovery and subsequent voltage-discrepancy accommodation.

Create a lesson

Metadata

Categories
eess.SY, cs.SY, eess.SP
Journal
Energy Storage Materials, Volume 91, 2026, Article 105553
Comments
Published in Energy Storage Materials, Volume 91 (2026), Article 105553. This is the authors' accepted manuscript. Please cite the Version of Record. Official published version: https://doi.org/10.1016/j.ensm.2026.105553