Gold nanorod radioenhancement: interpreting Monte Carlo dose enhancement across geometry, composition, coating, and localization
Ali Taheri, Hans Rabus, Mayeen Uddin Khandaker, Farhad Moradi, David Andrew Bradley
Abstract
Nanoparticle radiosensitization depends on interconnected NP properties, yet geometry, elemental composition, surface coating, and localization are typically studied separately, with their combined biological impact rarely assessed in one framework. Drawing on TOPAS Monte Carlo simulations from PhD research, we consolidated four investigations of metallic nanorods, mainly gold nanorods (AuNRs), examining these parameters across closely linked studies. The findings reveal that each parameter can influence over a distinct spatial range. Nanorod geometry primarily alters the spectrum and distribution of low-energy Auger-Meitner electrons emitted within tens of nanometers. Elemental composition induces significant near-field dose enhancement that rapidly attenuates and becomes negligible beyond roughly 1 um. Surface coatings reduce the fluence of secondary electrons below 3.5 keV, absorbed within about 150 nm of the surface, lowering physical dose contribution by 1-7%. Since coatings predominantly remove low-energy electrons, radiolytic yield changes through a shift in the electron energy spectrum, not directly following dose response. At the vascular scale, the enhanced dose region extends to approximately 10 um from the vessel wall, meaning NP localization determines where the biological target sits relative to radiation sources. Collectively, no single design parameter serves as a universal predictor of radiosensitization. Translating physical radioenhancement into biological effect depends on whether the target lies within each parameter's effective range. Furthermore, charged-particle equilibrium (CPE) correction, applied where beam confinement necessitated it, substantially alters calculated dose enhancement ratios. Consequently, scoring distance and CPE-corrected values should be explicitly reported to ensure comparability across studies.
Create a lesson
Related papers
An anatomically grounded human-scale dynamic model of contraction-driven lymphatic pumping
Chia-Feng Chang, Ayemon Baraka, Egor Sidorov et al.
An anatomically grounded human-scale steady hydraulic model of the lymphatic network
Chia-Feng Chang, Ayemon Baraka, Egor Sidorov et al.
Deep preferential evolution guided by pairwise comparisons enables motion correction in photoacoustic tomography
Karteekeya Sastry, Yousuf Aborahama, Junhao Zhu et al.
Technical Preparations for the First Carbon-Ion Therapy Facility in the United States
Jun Tan, Xiaoying Liang, Keith M Furutani et al.
How Can Technology Improve Acetabular and Pelvic Fractures Management in the Operating Room? A Systematic Review
Marie Le Baron, Martine Pithioux, Stéphane Candoni et al.
Laplace-Domain Beamforming for Ultrafast Plane-Wave Imaging
Martin F. Schiffner