Skip to content

One-Slide Calibration of Pathology Foundation Models

Ming Ren Hou, Tianyi Huang

cs.CV

Abstract

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses other regions within a slide as internal controls to predict a query region's scanner-induced shift. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Replacing controls with unrelated same-scanner regions reveals a positive same-slide contribution in all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

Create a lesson

Metadata

Categories
cs.CV, cs.AI
Comments
Accepted at the NeurIPS 2026 Workshop AI at Scale for Clinical Impact (ASCI): Cancer Pathology Foundation Models