An Arduino Giga-Based Multi-Frequency Electrical Impedance Tomography System for Electrolyte Media: Hardware Design, Statistical Voltage Analysis, and System Performance Evaluation
Zahra Karimi, Natalie Verdugo, Joseph Schwab, Hamid Ghaednia
Abstract
Multi-frequency electrical impedance tomography (EIT) often requires specialized hardware. This challenge is especially pronounced in biomedical applications. We developed a 16-electrode EIT system using an Arduino GIGA R1 WiFi for generation and acquisition, with a discrete current source, three analog multiplexers, and basic signal conditioning. Dual cores separate waveform timing from switching and acquisition. A 3D-printed tank with silver-wire electrodes was tested at 11 frequencies (1-180 kHz). Across the 10-180 kHz analysis band, median repeat-frame signal-to-noise ratio was 48 dB, acquisition rate was ~0.18 frames/s per frequency (~60 s per sweep), and cross-session baseline drift was ~6%. KCl phantoms contained an insulating ABS cylinder or KCl-filled dialysis bags (0.001-1.0 M) spanning positive and negative conductivity contrasts. Boundary voltages were analyzed without reconstruction to estimate inclusion position, contrast polarity, and relative magnitude. Leave-one-session-out matching located ABS inclusions in 29/30 runs at 160 kHz (87-97% across the band; chance 33%). For dialysis bags, polarity was correctly identified in all 36 nonzero-contrast runs. Signed voltage projections correlated with the cylindrical contrast factor (R2=0.68 across runs; R2=0.89 for the aggregate fit). Concentration was ordered (Spearman rho=0.85), despite saturation above ~10-fold contrast. Bag position accuracy ranged from 6/6 at the highest contrasts to 2/6 at matched conductivity. The matched-conductivity bag produced a ~1.7% RMS perturbation against 0.4-0.6% repeat-frame variability. These results demonstrate that microcontroller-based multi-frequency EIT can support selected detection and identification tasks through direct boundary-voltage analysis, supporting future studies of muscle electrochemistry.
Create a lesson
Related papers
Hardware-friendly Baseband Design and Performance Analysis for LEO Broadband LoS-MIMO Systems
Shared title terminologyeess.SPPeixin Zhang, Fengkui Gong, Guo Li et al.
An Efficient Correlation-based Evaluation of the GN-Model for General Multi-Span Optical Systems
Shared title terminologyeess.SPY. Jiang, Y. Gao, P. Poggiolini
VEGA: A Scalable Software-Hardware Co-design for Genome Alignment using RVV Extension
Shared title terminologyeess.SPWeihong Xu, Shijie Xu, Qunyou Liu et al.
Hardware Impairment Parameter Estimation in Fluid Antenna Systems by Inverse Optimization
Shared title terminologyeess.SPSongling Zhang, Zhaohui Yang, Ruopeng Xu et al.
Multi-Library Feature Engineering and Statistically Validated Classification for Power Swing Detection and Stability Assessment
Shared title terminologyeess.SPPallav Kumar Bera, Samita Rani Pani, Ranjeeta Patel
Exploiting Beam Squint for Near-Field Wideband Beamforming in Multi-User OFDMA Systems
Shared title terminologyeess.SPLanqing Zhi, Peilan Wang, Jun Fang