Modal estimation of high-order wavefront drifts on coronagraphic testbeds for high-contrast direct imaging of exoplanets
Saikrishna Manojkumar, Susan F. Redmond, Leonid Pogorelyuk, Ajay S. Gill, Laurent Pueyo, Emiel H. Por, Iva Laginja, Raphaël Pourcelot, Bryony F. Nickson, Ananya Sahoo, Meiji M. Nguyen, Rémi Soummer, Marshall D. Perrin, Bijan Nemati, Jeremy N. Kasdin, Kerri Cahoy
Abstract
Long-term wavefront stability will be critical for the upcoming Habitable Worlds Observatory which aims to directly image exo-Earths. Mechanical and thermal instabilities induce slow, high-order wavefront errors which can degrade the contrast and in turn, the scientific yield of the observatory. Dark zone maintenance (DZM) has been proposed as a high-order wavefront sensing and control strategy to maintain contrast despite wavefront error drifts. This approach uses an Extended Kalman Filter (EKF) to estimate the electric field at each pixel in the dark zone of the science camera. However, relying on individual pixel information to estimate wavefront errors can discard information stored in the underlying wavefront. This is a fundamental limitation on the best achieved contrast compared to the model based theoretical bounds derived from photon noise. An alternative EKF can incorporate more holistic information by estimating the drifting wavefront modes present in the system. In this work we analyze the performance of this Modal EKF on the High-contrast Imager for Complex Aperture Telescopes (HiCAT) simulator at the Space Telescope Science Institute. A parameter scan is performed across key variables: deformable mirror (DM) drift, the direct photon rate at the telescope aperture governing the mean number of photons in the dark zone (DZ), and the dither magnitude used to provide phase diversity. While prior studies explored a range of dither magnitudes, this work introduces a covariance-based approach within the Extended Kalman Filter (EKF) framework to optimally determine the probe magnitude required. Results from the modal EKF demonstrate a 15-fold improvement in contrast relative to the single-pixel DZM experiments, reducing the gap to within a factor of 2-3 of the theoretical bounds.
Create a lesson
Related papers
Focal plane modal estimation of high-order wavefront drifts on coronagraphic testbeds
Shared title terminology · Saikrishna Manojkumar, Susan F. Redmond, Leonid Pogorelyuk et al.
The MIRI/MRS Library. III. Detector-based optimal spectral extraction and high-contrast imaging applications
Shared title terminology · Danny Gasman, Ioannis Argyriou, David R. Law et al.
Mid-IR Water-Vapor Seeing: Implications for ELT/METIS High-Contrast Imaging from VLTI Data
Shared title terminology · Abhirami S Raghu, Prashant Pathak, Olivier Absil et al.
Improved compensation for missing high-order aberrations with multi-frame blind deconvolution and phase diversity techniques
Shared title terminology · G. B. Scharmer
Model-Based Low-Order Wavefront Sensing and Control with a Fully Physical Digital Twin on MagAO-X
Shared title terminology · M. Mars, S. Y. Haffert, J. R. Males et al.
Characterization of the GIGAPYX-4600 CMOS visible image sensor in the context of high precision astrometry
Shared title terminology · Manon Lizzana, Hugo Rousset, Sebastien Soler et al.