Skip to content

Maximum-Temperature Theorem for Nanothermometry

Taras Plakhotnik

cond-mat.stat-mech

Abstract

We derive a sharp upper bound on the quasi-steady temperature rise of a sensor of arbitrary shape and known thermometric volume VsV_\mathrm{s}, placed anywhere inside a region enclosed by an isothermal reference surface. The bound also requires the maximum net heat power Q˙S⊆Vrmax⁡\dot Q_{\scriptscriptstyle \mathcal S \subseteq \mathcal{V}_{\mathrm r}}^{\max} crossing any closed surface within the region and a lower bound on its thermal conductivity κVrκ_{\scriptscriptstyle{\mathcal{V}_{\mathrm r}}}. It is otherwise independent of the heat-source distribution, domain shape, and source-ensor distance. For Q˙S⊆Vrmax⁡=50 pW\dot Q_{\scriptscriptstyle \mathcal S \subseteq \mathcal{V}_{\mathrm r}}^{\max}=50~\mathrm{pW}, κVr=0.1 W m−1K−1κ_{\scriptscriptstyle{\mathcal{V}_{\mathrm r}}} =0.1~\mathrm{W\,m^{-1}K^{-1}}, and VsV_{\mathrm s} equal to the volume of a 60 nm60~\mathrm{nm}-diameter sphere, the theorem permits a maximum temperature rise of approximately 2 mK2~\mathrm{mK}. Neither source localization nor uncertain source--sensor separation can therefore account for reported kelvin-scale intracellular readings under steady-state heat conduction. The result applies to sensors based on nanodiamonds, upconversion nanoparticles, fluorescent polymer beads, and core-shell quantum dots.

Create a lesson

Metadata

Categories
cond-mat.stat-mech, cond-mat.mtrl-sci, physics.class-ph
Comments
10 pages, 3 figures Clarified heat-power definition, notation and the title. Added transient temperature case (in Supplemental Materials). Main results are unchanged