End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI
Lukas T. Rotkopf, Marco Schlimbach, Kevin Kröninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe
Abstract
Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.
Create a lesson
Metadata
- Categories
- cs.CV, physics.med-ph
Related papers
An Agentic AI Workflow for Liver Lesion Segmentation and Structured Radiology Reporting
Shared title terminologycs.CVFatma Ahmed Mansour, Rahatara Ferdousi, Zyad Medhat Mahmoud Ashor et al.
On Detection Reliability for Small Object Segmentation
Shared title terminologycs.CVOlivier Rukundo
Rank-1 Weight-Corrected Trainable Weight Averaging for Out-of-Distribution Detection
Shared title terminologycs.CVAkito Shinohara, Hiroaki Aizawa
DiffusedSplitFed: Latent Diffusion-based Obfuscation for Reconstruction-Resilient Split Federated Medical Image Segmentation
Shared title terminologycs.CVChamani Shiranthika, Parvaneh Saeedi
SCDM-HTD: Spectral-Wise Conditional Diffusion Model for Hyperspectral Target Detection
Shared title terminologycs.CVDunbin Shen, Wenfeng Kong, Jianjun Liu et al.
Back to Raw Motion: Latent-Free Diffusion Transformers for Text-to-Motion and Exact Conditional Generation
Shared title terminologycs.CVYun Chen, Jeonghyeok Do, Munchurl Kim