Real-time volumetric MRI-guided MLC tracking: A feasibility study
Tianyu Yang, William P Donahue, Aniket Pramanik, Victor Murray, Can Wu, Ricardo Otazo, Grace Tang
Abstract
Background and purpose: The MR SIGnature MAtching (MRSIGMA) was recently proposed as a real-time free-breathing 3D MR imaging technique with an imaging latency of 148 ms. It is a powerful tool for intrafractional motion monitoring for disease sites such as those in the abdominal region. This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac. Material and methods: An MLC tracking interface was developed for integration with MRSIGMA. The centroid position of a moving target was computed in real time by MRSIGMA, which was then processed by a predictive filter to account for imaging and MLC adjustment latencies. The MLC leaves were repositioned by rigid translation. To validate the MLC tracking process, a 10 cm circular field was delivered to a moving phantom for a series of sinusoidal motions and patient motion. A clinical pancreas SBRT plan was also delivered with the patient motion trace. Results: For the circular field, geometric errors of <1.8 mm and overall system latency of < 125 ms were achieved for all motion traces. Compared to no tracking, MLC tracking remarkably improved the dosimetric accuracy for the circular field and the clinical pancreas plan, with an average Gamma passing rate increased from 87.1% to 99.9% based on a 3%/2mm criteria. Interpretation: A 3D MRI-guided MLC tracking technique was developed and validated on a clinical MR-Linac. Preliminary results demonstrated great dosimetric improvements with MLC tracking for treatments with moving targets.
Create a lesson
Related papers
Just-in-time volumetric imaging: Learning 2D-3D thoracic motion models during image-guided interventions
Shared title terminology · Nicholas Hindley
GenMC: Real-Time Generative Monte Carlo Surrogate for Quantitative Photoacoustic Imaging
Shared title terminology · Mengjie Shi, Feng He, Tom Vercauteren et al.
Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
Shared title terminology · Javier Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco et al.
An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study
Shared title terminology · Yizhou Wu, Ryan J. Sanford, Huiqiao Xie et al.
Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR Brachytherapy
Shared title terminology · Kevin Willy, Megan Clark, Petr Bruza et al.
Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants
Shared title terminology · U-Wai Lok, Jingke Zhang, Jingyi Yin et al.