Skip to content

SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable Rendering and Continuous-Time Joint Optimization

Zhengdong Hong

cs.ROarXiv:2611.02999

Abstract

Markerless hand-eye calibration under continuous motion requires jointly resolving camera geometry and the time offset between images and joint states. We present SyncHeC (Synchronized Hand-Eye Calibration), a dense differentiable-rendering framework that estimates both from a single robot trajectory. Continuous-time forward kinematics makes latency differentiable, metric depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one 6.5\,s motion yields 0.21\,cm translation error against a marker-board reference, 0.34\,cm touch-test error, and 2.7\,ms latency error relative to an 87\,ms reference with 95\% uncertainty of 1.5\,ms. Against CM-Calib on matched recordings, translation and nominal latency errors improve by 3.7× and 2.3×. Experiments span seven arms and four depth sensors. Compensating the recovered offset during policy training and deployment increases success by 8.1 percentage points across six families and six tasks (1,800 matched pairs; paired 95\% confidence interval [6.3,9.9] points).