LCM-UNet: Scale-Selective Mamba with Reparameterizable Multi-Basis Local Modeling for Lightweight Skin Lesion Segmentation
Md Shihabul Islam Shovo, Nishi Kanta Paul, Dip Kumar Saha, Kishor Morol
Abstract
Accurate lesion segmentation underpins automated dermoscopic analysis: masks enable measurements of asymmetry, border and size. Deployment in primary care or on mobile devices requires a compact network. Existing ultra-light Mamba U-Nets offer global context, but global-modeling cost depends on each Mamba block's resolution, while their local branches rely on a single square kernel. We introduce LCM-UNet, a 33,474-parameter U-shaped network that fuses every skip at its native resolution, restricts bidirectional Mamba to stages at one-sixteenth of the input resolution or coarser, and uses local convolutions at finer scales. A multi-basis reparameterizable adapter augments each local branch during training with dilated, horizontal and vertical depthwise kernels, then folds them into the host kernel before inference. Each skip connection also learns a stage-specific gain. Nine networks were retrained on the official ISIC 2017 and ISIC 2018 partitions under a harmonized protocol, with PH reserved for external validation and ablations run on a development split. LCM-UNet achieved Dice scores of 88.62%, 89.73% and 90.46% on ISIC 2017, ISIC 2018 and PH, respectively, ranking first on both ISIC test sets and second on PH among the compared models. In the native-resolution host, removing Mamba from the one-eighth-resolution decoder stage eliminated 63% of Mamba operations, corresponding to 5.3% of all operations, with a Dice change of percentage points. The adapter improved Dice by 0.48 percentage points over a single host kernel without adding deployed parameters or operations. With latency so far measured only on a GPU, LCM-UNet is a candidate for resource-constrained deployment.
Create a lesson
Metadata
- Comments
- The authors request the withdrawal of this manuscript due to unresolved methodological and experimental validation concerns that may affect the reliability of the reported findings. The authors consider it inappropriate to retain the current version as an active preprint until these concerns have been adequately addressed
Related papers
Reliable Recursive Memory for Causal Multi-scale Video Polyp Segmentation
Shared title terminologycs.CVTong Wang, Wenbo Peng, Yaolei Qi et al.
Segment What It Can Draw: Querying a Text-to-Image Generator with Its Own Images for Skin Lesion Segmentation
Shared title terminologycs.CVHongyu Cao, Guangfu Guo, Jinghan Zhang et al.
MSW: a Multi-Scale Sliced Wasserstein Distance Between Image Distributions
Shared title terminologycs.CVYoussef Haouchat, Stanislas Ducotterd, Bassam El Rawas et al.
Go Far, Look Less: Active Multi-Room Reconstruction with Persistent Goals and Selective Views
Shared title terminologycs.CVJiawei Jiang, Haonan Zhou, Wendi Hu et al.
METRIC-GS: Selective Metric-Scale Estimation for 3D Gaussian Splatting
Shared title terminologycs.CVSooyeun Yang, Jongseong Brad Choi
Feature Puzzles: Single-Image Supervision for Multi-View 3D-Aware Segmentation
Shared title terminologycs.CVJiahao Ma, Qiang Zhang, Miaomiao Liu et al.