Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time Regularisation
Andrew J. Reader, Gary J. R. Cook, Paul K. Marsden, Sarah-May Gould, Alexander Hammers, Simon R. Cherry
Abstract
Kinematic PET is introduced as an imaging task focused on visualisation of early radiotracer delivery and rapid multi-organ motion without gating. The proposed kinematic video reconstruction method uses 33-ms frames (~30 frames per second), initialised with 3D expectation maximisation (EM) time of flight (TOF) list-mode reconstruction, followed by cycles of a 2-stage update. These 2 stages are i) a hierarchical EM (HEM) update using multiple temporal pooling levels, and ii) a validation-adaptive space-time (VAST) regularisation update. HEM combines frame-specific EM corrections with corrections estimated from higher-count temporal blocks, slowing noise amplification for the ultrashort frames. VAST mixes each 3D target patch in a frame with source patches sampled nearby in space and time. It selects the candidate that best matches the mean of the corresponding patches in the two adjacent frames, with the unchanged patch also eligible. Optional temporal block sum correction uses the initial EM temporal sum as a reference to reduce loss of spatial detail. HEM+VAST was evaluated with a dynamic digital phantom, and demonstrated on human FDG data acquired on a Siemens Biograph Vision Quadra (28 - 58 s post-injection). At a background spatial coefficient of variation of 10%, the temporal full width at half maximum of the fastest phantom bolus was 151 ms with HEM+VAST, compared with 86 ms for the ground truth. The video frame rate FDG images reveal vascular and organ detail, radiotracer bolus passage and respiration-related multi-organ motion. Kinematic PET could complement conventional dynamic PET by supporting the development of image-derived physiological biomarkers and motion estimation for quantitative reconstruction. Future work should compare HEM+VAST with prior 4D PET reconstruction methods at the same 33-ms frame duration and matched noise levels.
Create a lesson
Related papers
TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery
Shared title terminology · Niran Nataraj, Maina Sogabe, Norihiko Ito et al.
A four-step validation protocol for radiomic survival analysis in small cohorts: a body composition case study
Shared title terminology · Mariela Talavera-Muñoz, Cecilia Diana-Albelda, Miguel Antonio Sampedro-Nuñez et al.
Selecting Person Segmentation Models for Real-Time Video Call Backgrounds on the CPU
Shared title terminology · Kawshik Kumar Paul
Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI
Shared title terminology · Yan Chen, Curtis A. Corum, James H. Holmes et al.
HIVE-Diff: High Frame Rate HDR Video Reconstruction from a Single LDR Frame and Events
Shared title terminology · Caixin Wang, Qingrui Wang, Jie Zhang et al.
VC-1K: A Diverse Video Test Set for Real-Time Communication
Shared title terminology · Yu-Chen Sun, Jie Dong, Sergey Sablin et al.