RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation
Xinyuan Wang, Ruili Li, Tianyang Li, Yan Li, Xuepeng Liu
Abstract
Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.
Create a lesson
Related papers
LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising
Shared title terminology · Fatma Elif Yalçındağ, Mehmet Ozan Ünal, Metin Ertaş et al.
Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment
Shared title terminology · Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal et al.
Joint Image Denoising and Interpolation via Mixed Graph Filtering
Shared title terminology · Gene Cheung, Niruhan Viswarupan, Romisaa Elsaidy
Equal Dose, Different Coverage:Tracing Rate and Duration in Image Editing
Shared title terminology · Yi Liu
A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema
Shared title terminology · Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani et al.
Cross-Layer Refinement and Frequency-aware Fusion Network for Multi-Source Remote Sensing Image Classification
Shared title terminology · Wenhan Xiao, Chuanzheng Gong, Feng Gao et al.