Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT
Sungho Yun, Seungryong Cho
Abstract
Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.
Create a lesson
Related papers
Towards consensus on practical probabilistic evaluation metrics for clinical decision making in radiotherapy
Jenneke I. de Jong, Steven J. M. Habraken, Erik W. Korevaar et al.
Unmyelinated axons alter the biological interpretation of MRI biomarkers of demyelination
Ali Abdollahzadeh, Ricardo Coronado-Leija, Elizabeth Chasen et al.
Impact-Based Analysis Method (IBAM) to evaluate the primary stability of the pedicle screw: A proof of concept
Julie Gabriel, Yvan Petit, Giuseppe Rosi et al.
The relationship between junctional zone, smooth muscle tone and intra-uterine pressure
Nicolas R. Chevalier, Emilie Huon, Julie Poujol et al.
A Soft Sponge-Pillar Electrode Platform for Motion-Tolerant Ambulatory EEG and Sleep Monitoring
Chansoo Kim, Weilun Li, Ryan Andersen et al.
Using an instrumented hammer to predict the lateral hinge fracture in high tibial osteotomy: A cadaveric study
Claire Bastard, Manon Bas-Dit Nugues, Giuseppe Rosi et al.